PIPESTRESS performs a complete ASME fatigue analysis, verifying the 12 conditions shown in the FATIGUE ANALYSIS LEGEND below.  See fatigue analysis summary.

 

PIPESTRESS has been used to perform fatigue analysis calculations in nuclear plants in the USA, Mexico and Europe for design, maintenance and lifetime extension.

 

DST engineering staff is highly experienced in performing fatigue analysis calculations with PIPESTRESS.  They are available to assist clients, both for training and consulting.

 


 

D S T   C O M P U T E R   S E R V I C E S   S. A.        G E N E V A                      F-3                   PAGE NO. 259

 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
 ++ DST/PIPESTRESS ++                  NUCLEAR POWER PLANT S. BOONE                 Version 3.5.0+417  PC         Release: Sep 1999
 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

     CALCULATION NUMBER 3999         CODE SECTION III CLASS 1  ASME-1977          TEST PROBLEM NO. 1   2001/01/15  14:36:18  [304]
       CLASS 1 ANALYSIS FATIGUE PROTECTION                      INCLUDING STATIC AND SEISMIC LOADS, AND TRANSIENT

                        FATIGUE ANALYSIS LEGEND
                        ------------------------

                        Note   Condition               Remark
                        -------------------------------------
                          a    UF > 1.0                Fails
                          b    Eq 10 > 3.0 SM          Fails
                          d    Eq 12 > 3.0 SM          Fails
                          e    Eq 13 > 3.0 SM          Fails
                          f    UF > 0.4                Weld in Service Inspection (ISI)
                          g    Eq 10 > 2.4 SM          Weld in Service Inspection (ISI)
                          h    Eq 12 > 2.4 SM          Rupture Location
                          i    Eq 13 > 2.4 SM          Rupture Location
                          j    UF > 0.1                Rupture Location
                          k    deltaT1 range > allow   Fails
                          l    deltaT1 range > allow   Information
 